This is the most common reason people call us. You’re adding a loft room, and Building Control or your architect has told you the open-plan kitchen and living space downstairs won’t pass. Here’s why, and what you can do about it.
Why a loft conversion changes things
Adding a loft room puts another storey above the ground floor and increases the distance people have to travel to get out. Approved Document B then normally expects a protected escape route: an enclosed stairway and hall that leads straight to an exit, so someone on the top floor can get out without passing through a room where a fire might start.
An open-plan ground floor, where the stairs come down into the kitchen or living area, breaks that route. A fire in the kitchen would block the way out.
Your options
- Put the walls and doors back and enclose the stairway and hall. It works, but you lose the open-plan layout.
- Fit fire suppression to protect the open-plan area, so you keep the layout. Approved Document B allows other ways of meeting the regulations where its standard guidance isn’t followed, and suppression is a widely accepted way of doing this.
Automist is designed for exactly this. An independent fire engineering assessment found it to be equivalent to, or better than, a domestic sprinkler to BS 9251 for open-plan homes over two storeys. And it doesn’t need a water tank or pipework across every ceiling. See Automist vs sprinklers.
What Building Control will check
- That the open-plan area is fully covered.
- That cupboards or pantries with doors larger than 2 m², and hallways wider than 1 m, are covered too. These are common reasons proposals get sent back.
- That the rest of the fire strategy is in place, such as smoke alarms. Automist’s detectors only trigger the Automist system, so you still need your normal smoke alarms.
Get us involved early
The best time to talk to us is before your Building Control submission. Send us your drawings and we’ll design the system layout, so you or your architect can submit it with the plans. We fit the pipework and cables at first fix while walls and ceilings are open, then come back to fit and commission the system at the end of the build. See how the process works →
Watch: how Automist helps open-plan homes meet the Building Regulations (Plumis).
Send us your drawings (a photo of them is fine) and we’ll come back with a design and a full quote, usually before anyone needs to visit site. Send your plans →
Please note: as an authorised installer we design to the brief we’re given, but we can’t decide what fire protection your property needs. That decision, and final sign-off, rests with Building Control or the relevant authority.